Seite 1 - SHDTU03b NTU Series

SHDTU03b NTU Series G.SHDSL.bis TDM NTU

Seite 2

10 1.1 Features y Standard G.SHDSL.Bis ITU G.991.2 (2004) supports improved reach/speed and greater interoperability y Fast and cost-effective pro

Seite 3

100 Setup E1 Parameter, AIS AIS (Alarm Indication Signal) is a method to inform the remote connection that there is a signal o

Seite 4

101 Setup E1 Parameter, Build Out The SHDSL.Bis NTU can support both unbalanced E1 at 75 ohms (BNC) and balanced E1 at 120 ohms (R

Seite 5 - Tables of Contents

102 5.4.4. Configure Serial parameters When using the Serial interface, select the Serial item and press [ENTER] or [RIGHT]. The serial settings in

Seite 6

103 Setup Serial Parameter, Data Rate For 2-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 64kbps

Seite 7

104 Setup Serial Parameter, RTS The behavior of the RTS (Request To Send) signal may be set in one of two ways. When set 'on&ap

Seite 8

105 Setup Serial Parameter, DSR The behavior of the DSR (Data Set Ready) signal may be set in one of three ways. When set 'on&a

Seite 9 - 1. Introduction

106 Setup Serial Parameter, Delay The delay setting is used to cause a delay for CTS to follow RTS. The delay setting may be set 0,

Seite 10 - 1.2 Specification

107 Setup Ethernet Parameter, Data Rate – Rate type There are two modes: Nx64K model and T1 mode. When the remote side has T1 inter

Seite 11 - 1.3 Applications

108 Setup Interface Parameter, Negotiation The Ethernet settings include the choice between auto-negotiation (default) or forced mod

Seite 12 - 2.1 Front Panel

109 Setup Ethernet Parameter, Speed When auto negotiation is Disable, the forced mode settings for speed can be set between: 10M and

Seite 13

11 Performance Monitoring • ES, SES, UAS, LOWS for SHDSL • ES, SES, UAS for E1 • Alarms and Errors for SHDSL or interface Loopback Tests (for E1,

Seite 14

110 Setup T1 Parameter, Channel The Superframe(SF) (also called D4 or 193S) framing format defines a superframe as 12 frames. The E

Seite 15 - 2.2 Rear Panel

111 Setup T1 Parameter, Time Slot number and First time slot For fractional T1, the data rate is from 64k(N=1) to 1536k(N=24), acco

Seite 16

112 The table of number of time slot vs. 1st time slot: Channel Number of slot 1st slot 24 1 23 1~2 22 1~3 21 1~4 20 1~5 19 1~6 18 1~7 17 1~8 16 1~9

Seite 17

113 Setup T1 Parameter, AIS AIS (Alarm Indication Signal) is a method to inform the remote connection that there is a signal or sy

Seite 18

114 5.4.8. Restore factory default The G.SHDSL .Bis NTU can restore all settings to the original factory settings simply by going to the setting me

Seite 19 - 2.3 Installation

115 Ethernet Setup Ethernet Rate Type Setup Ethernet Rate setup Ethernet Auto Config setup Ethernet Speed setup Ethernet Duplex Nx64K 36 Enable Auto

Seite 20 - 2.3.1. E1/T1 Interface

116 T1+ Serial setup T1 Channel setup T1 Slot Number setup T1 First Slot setup T1 AIS setup T1 Lbo setup Serial Interfac

Seite 21 - 2.3.2. Serial Interface

117 5.5 Reboot In main menu, move the cursor to reboot and press [ENTER]. The device will reboot after confirming.

Seite 22 - 2.3.3. Ethernet Interface

118 5.6 View the system status You can use the status command to view the status of SHDSL, E1, Serial and Ethernet as well as statistic and clear t

Seite 23 - Protective earth:

119 The SHDSL status will display a real-time status of the DSL on local side and remote side if connected. The monitoring window

Seite 24 - 3.1 Keypad

12 2. Getting to know the SHDSL.bis NTU This chapter shows the front and rear panel and how to install the hardware. The models listing on G.SHDSL

Seite 25 - 3.2 Main menu Tree

120 The interface status will display a real-time status of the interface on local side and remote side if connected. The monitorin

Seite 26

121 The table of SHDSL line rate vs. data rate: Data Rate (kbps) SHDSL Line rate Number of time slot for E1 Nx64K for Serial and Ethernet 5696(n=89)

Seite 27

122 5.6.3. View the Statistics Select Loc_statistics command to show the Local statistics information in 15 minutes or 24 hour via [TAB] to choose.

Seite 28

123 For E1 Interface model, there are SHDSL and E1 items. View the performance monitor data for the selected interval 15 minutes: V

Seite 29

124 For Serial and Ethernet Interface model, there is only the SHDSL item. View the performance monitor data for the selected interval 15 minutes:

Seite 30

125 When clear the statistic log file, select clear and press [ENTER]. If you want to show the remote side’s statistics, please

Seite 31

126 The following are commonly used acronyms: ES Number of errored seconds in which one or more CRC (Cyclic Redundancy Check) error events occurr

Seite 32

127 5.7 View System Configuration By using show command, you can view the system configuration. Select show and press [ENTER] or [RIGHT].

Seite 33

128 Our cursor is already on the System command, so press ENTER and the following screen will display the general system information.

Seite 34

129 5.7.2. Show system with listing format To show the system configuration, please select Config and press [ENTER] or [RIGHT]. The screen will prom

Seite 35

13 2.1.3. Ethernet interface model 2.1.4. Multi-interfaces model Front panel can be separated into three parts: LCD display, L

Seite 36

130 For Ethernet interface mode: For E1 and Serial interface mode:

Seite 37

131 For E1 and Ethernet interface mode: 5.7.3. Show system with script format To show the system script file, please select Sc

Seite 38

132 For E1 interface mode: For Serial interface mode:

Seite 39

133 For Ethernet interface mode: For E1 + Serial interface mode:

Seite 40

134 For E1 + Ethernet interface mode:

Seite 41

135 5.8 Upgrade This section will introduce how to upgrade the kernel and FPGA code of G.SHDSL .Bis NTU. Select upgrade in main menu and press [ENT

Seite 42

136 During the upgrade, you can see the following: If you want to upgrade the FPGA code: Select FPGA and press [ENTER] or [RIGHT].

Seite 43

137 During the upgrade process, you will see the following: Below shows the remote upgrade feature:

Seite 44

138 During the upgrade, the display will look like the following: Before upgrading the NTU, you must have the Kernel code and FPGA

Seite 45

139 5.9 Diagnostic The diagnostic facility allows you to test the different aspects of your G.SHDSL .Bis NTU to determine if it is working properl

Seite 46

14 On E1 line is connected. SYN Green Off E1 line is dropped. Blink There are error seconds. ERR Red Off There is not any error second. On Loopba

Seite 47

140 If the device has just been connected or the DSL is still under handshaking, there will not are farend line, farend payload and V.54.There are no

Seite 48

141 The SHDSL.bis NTU supports Bit Error Rate Testing (BERT). To configure the BERT, move the cursor to BerTest and press [ENTER] or [RIGHT].

Seite 49

142 5.10 Exit For exiting the system without saving any configuration, you can use exit command to exit. Select exit and press [ENTER] or [RIGHT].

Seite 50

143 When the system has been disconnected, user can see the close screen. You can press Space key to restart. The new login screen w

Seite 51

144 6. Appendix 6.1 Abbreviations AIS Alarm Indication Signal AMI Alternate mark inversion ASYM Asymmetric ATM Asynchronous Transfer Mode B8ZS

Seite 52

145 I/F Interface ITU International Telecommunication Union ITU-T ITU-Telecommunication Standardization Sector LBO Line Build Out LIU Line Interfa

Seite 53

146 STU-R-EXTCLK STU-R external clock SYM Symmetric SYNC Synchronization TC-PAM Trellis Coded Pulse Amplitude Modulation TDM Time Division Multipl

Seite 54

147 6.2 Serial Interface Pin Assignments The table below displays Serial Interface Pin Assignments for the DCE Mode . Function Abbrev. Direction

Seite 55

148 6.3 V.35 DB25(M) to M.34(F) adaptor Cable If the DTE (Data Terminal Equipment) connector is using 34-pin Winchester type, we must use the cable

Seite 56

149 V.35 interface (34-pin Winchester type) contains the following signals: Pin Signal Abbr. DTE DCE A Chassis Ground FGND --- --- B Signal Gro

Seite 57

15 2.2 Rear Panel 2.2.1. E1/T1 Interface Model AC power input version The rear panel of this model is including power switch, AC power soc

Seite 58

150 6.4 X.21 DB25(M) to DB15(F) adaptor Cable For X.21 applications, we must use the DB-25 to DB-15 adaptor cable to connect to a X.21 DTE DB-15 mal

Seite 59

151 The pin out of DB-15 connector on X.25 adaptor cable: Pin Signal Abbr. DTE DCE 1 Shield -- -- -- 2 Transmit (A) TA Out In 3 Control (A) C

Seite 60

152 DCD1RXD2TXD3DTR4GND5DSR6RTS7CTS8DSR1DCD2DTR3GND4RXD5TXD6CTS7RTS8NC9DB9 (Female) RJ-45 6.5 Console Cable The front view of RJ-45 console cabl

Seite 61

153 6.6 E1/T1 Balanced Cable The front view of RJ-48C E1/T1 balance cable socket on rear panel: The pin out of RJ-48C plug

Seite 62 - 3.7.1. Loopback function

154 6.7 E1 Unbalanced Cable Connections to the E1 BNC ports are made using a 75-ohm coaxial cable with a bayonet-style twist-lock BNC conne

Seite 63

155 6.8 Ethernet Cable The Ethernet cables should be 4 pair unscreened cable (UTP) or screened (STP) of type CAT5 (or higher). Both crossed a

Seite 64

156 6.9 DSL Cable The front view of DSL cable socket on rear panel: The pin out of RJ-45 modular jack on DSL cable: Pin Number Descri

Seite 65 - 3.7.2. BER Test function

157 6.10 Power Cord The front view of IEC-320 C6 type AC Inlet on rear panel: The pin out of AC Inlet connector: Pin number Desc

Seite 66 - 4. Parameters Table

158 6.11 Illustration of Loopback connection device (E1) RJ-48C Pin number Description 4 Transmit Ring 3 Rx Shield 1 Receive Ring 6 TX Shie

Seite 67 - 4.2 SHDTU03b-Data

159 6.12 Illustration of Loopback connection device (Serial) DB-25(M) Pin number Signal Description 2 TD(A) Transmit Data 14 TD(B) Transmit D

Seite 68 - 4.3 SHDTU03b-ET100

16 2.2.2. Serial Interface Model AC power input version The rear panel of this model is including power switch, AC power socket, RJ-45 for

Seite 72 - E1+Serial □E1+Ethernet

17 2.2.3. Ethernet Interface Model AC power input version The rear panel of this model is including power switch, AC power socket, RJ-45 fo

Seite 73 - E1+Ethernet

18 2.2.4. Multi-interfaces in one Model DC power input version The rear panel of this model is including power switch, AC power socket, RJ-4

Seite 74 - 4.5 SHDTU03b-E1/T1

19 2.3 Installation Note: To avoid possible damage to this NTU, do not turn on the product before hardware installation. (a) Plug the power cord

Seite 76 - 4.6 SHDTU03b-31T

20 2.3.1. E1/T1 Interface AC power input version DC power input version AC & DC dual power input v

Seite 77

21 2.3.2. Serial Interface AC power input version DC power input version AC & DC dual power input vers

Seite 78

22 2.3.3. Ethernet Interface AC power input version DC power input version AC & DC dual power input vers

Seite 79

23 ! Protective earth: The marked lug or terminal should be connected to the building protective earth bus. The function of protective earth do

Seite 80

24 3. Configuration with Keypad and LCD This chapter provides information about the configuration of your G.SHDSL .Bis NTU via front panel LCD disp

Seite 81

25 3.2 Main menu Tree Model vs. Interface modes support (table 1): Model Interface modes support SHDTU03b-E1; SHDTU03bA-E1 E1 interface model E1 i

Seite 82

26 After turning on device, the LCD display will prompt G.SHDSL .BIS NTU. Press Enter to enter. The display will follow the sub-menus as in the follow

Seite 83 - T1+Ethernet

27 3.3 Menu tree for SHOW STATUS You can check the status via LCD display. The SHOW STATUS menu tree is as following.

Seite 84

28 For more detail on these sub-menus, please refer to following:

Seite 85 - 5.1 Login Procedure

29 3.4 Menu tree for SHOW STATISTICS The product can display two kinds of statistics data: (a) Current 15 minutes period and 96 previous 15-minu

Seite 86 - 5.2 Window structure

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District Taipei 114 Taiwan

Seite 87 - 5.3 Main Menu Summary

30 Model vs. Interface modes and statistics support: Model Interface modes support SHDSL statistics support ES ,SES,UAS,LOSWE1 statistics support ES,

Seite 88 - 5.4 Configuration

31 3.4.1. Show Statistic on E1 Interface

Seite 89

32 3.4.2. Show Statistic on Serial/Ethernet/T1 Interface

Seite 90

33 3.5 Menu tree for SYSTEM SETUP You can setup five interface modes via LCD display.

Seite 91

34 3.5.1. Sub-Menu tree for SETUP SHDSL SETUP SHDSL Selection items SETUP MODE STU-R, STU-C-INTCLK, STU-C-EXTCLK SETUP ANNEX A,

Seite 92

35 3.5.2. Sub-Menu tree for SETUP E1 Interface SYSTEM SETUP Î SETUP E1 E1 parameter setting: E1 Items Setting Channel

Seite 93

36 Framer Setting: Framer Slot Number First Slot PCM31 FAS 1 to 31 1 to 31 PCM31C FAS+CRC4 1 to 31 1 to 31 PCM30 FAS+CAS 1 to 30 1 to 31 (c

Seite 94

37 25 1~6 24 1~7 23 1~8 22 1~9 21 1~10 20 1~11 19 1~12 18 1~13 17 1~14 16 1~15 15 1~15,17 14 1~15,17~18 13 1~15,17~19 12 1~15,17~20 11 1~15,17~21 10 1

Seite 95 - Framing

38 16 1~15 14 1~15,17~18 12 1~15,17~20 10 1~15,17~22 8 1~15,17~24 6 1~15,17~26 4 1~15,17~28 2 1~15,17~30 Note: When SHDSL.bis uses 2-pairs(4-wires),

Seite 96

39 3.5.3. Sub-Menu tree for SETUP SERIAL Interface SYSTEM SETUP Î SETUP SERIAL

Seite 97 - Unframed E1

Legal The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union T

Seite 98

40 Serial interface control signals settings: Serial Items Setting INTERFACE V.35 X.21(RS-530) T1 mode Annex A/B 1 ~ 36 2-wires Annex F/G 1 ~ 89 A

Seite 99

41 The handshake signal direction between DCE and DTE The below diagram shows CTS follow RTS, DSR follow DTR The RTS delay tim

Seite 100 - Setup E1 Parameter, AIS

42 3.5.4. Sub-menu tree for SETUP Ethernet Interface SYSTEM SETUP Î SET UP ETHERNET If you set Ethernet Auto Negotiation to En

Seite 101

43 3.5.5. Sub-menu tree for SETUP T1 Interface SYSTEM SETUP Î SETUP T1 T1 parameter setting: T1 Items Setting Channel SF ESF

Seite 102

44 The table of number of time slot vs. 1st time slot: Annex A/B/F/G 2-wire Channel Number of slot 1st slot 24 1 23 1~2 22 1~3 21 1~4 20 1~5 19 1~6

Seite 103

45 3.5.6. Application of STU-R configuration follow STU-C Some configurations on STU-R side can follow STU-C side after DSL link up is finish. Such

Seite 104 - Setup Serial Parameter, CTS

46 3.5.7. Application of Multi-interface Dual interface vs. Dual interface Case 1 E1(Unframed)+ Serial interfac

Seite 105

47 Table of E1+ Serial interface or E1+Ethernet interface mode on both sides Annex A /B (2-wires) E1 interface Serial interface Ethernet interface C

Seite 106

48 16 1 1~20 15 1 1~21 14 1 1~22 13 1 1~23 12 1 1~24 11 1 1~25 10 1 1~26 9 1 1~27 8 1 1~28 7 1 1~29 6 1 1~30 5 1 1~31 4 1 1~32 3 1 1~33

Seite 107

49 30 1 1~59 29 1 1~60 28 1 1~61 27 1 1~62 26 1 1~63 25 1 1~64 24 1 1~65 23 1 1~66 22 1 1~67 21 1 1~68 20 1 1~69 19 1 1~70 18 1 1~71 17 1

Seite 108

Tables of Contents 1. INTRODUCTION ...

Seite 109

50 26 1 1~46 24 1 1~48 22 1 1~50 20 1 1~52 18 1 1~54 16 1 1~56 14 1 1~58 12 1 1~60 10 1 1~62 8 1 1~64 6 1 1~66 4 1 1~68 2 1 1~70 Annex F/

Seite 110 - Setup T1 Parameter, Channel

51 Case 5 T1(Unframed)+ Serial interface Å---------Æ T1(Unframed)+ Serial interface Case 6 T1(Framed)+ Serial

Seite 111

52 Table of T1+ Serial interface or T1+Ethernet interface mode on both sides Annex A/B (2-wire) T1 interface Serial interface Ethernet interface Cha

Seite 112 - Setup T1 Parameter, LBO

53 6 1 1~83 5 1 1~84 4 1 1~85 3 1 1~86 2 1 1~87 1 1 1~88 Annex A/B (4-wire) T1 interface Serial interface Ethernet interface Channel Number of slot

Seite 113 - 5.4.7. Remote configuration

54 Dual interface vs. Single interface Case 9 E1(framed)+ Serial interface Å---------Æ E1(framed) Case 10 E1(framed)+Ethernet

Seite 114

55 Table of E1+ Serial interface to E1 interface and E1+Ethernet interface to E1 interface mode on both sides Annex A /B/F/G (2-wires) E1 interface

Seite 115

56 13 1 1~17 12 1 1~18 11 1 1~19 10 1 1~20 9 1 1~21 8 1 1~22 7 1 1~23 6 1 1~24 5 1 1~25 4 1 1~26 3 1 1~27 2 1 1~28 1 1 1~29 Annex A /B/F/G (4-wires)

Seite 116

57 24 1 2,4,6 23 1 1,3,5,7 22 1 2,4,6,8 21 1 1,3,5,7,9 20 1 2,4,6,8,10 19 1 1,3,5,7,9,11 18 1 2,4,6,8,10,12 17 1 1,3,5,7,9,11,13 16 1 2,4,6,8,10,12,14

Seite 117 - 5.5 Reboot

58 Case 11 T1(framed)+ Serial interface Å---------Æ T1(framed) Case 12 T1(framed)+Ethernet interface Å---------ÆT1(framed)

Seite 118 - 5.6 View the system status

59 Table of T1+ Serial interface to T1 interface and T1+Ethernet interface to T1 interface mode on both sides Annex A /B/F/G (2-wires) E1 interface

Seite 119

4.4 SHDTU03B-31... 69

Seite 120

60 7 1 1,3,5,7,9,11,13,15,17 6 1 2,4,6,8,10,12,14,16,18 5 1 1,3,5,7,9,11,13,15,17,19 4 1 2,4,6,8,10,12,14,16,18,20 3 1 1,3,5,7,9,11,13,15,17,19,21 2 1

Seite 121

61 3.6 Sub-menu tree for REBOOT SYSTEM REBOOT SYSTEM -> * REBOOT * YES -> press ”ENTER” key Some settings request system reboot for the sett

Seite 122 - 5.6.3. View the Statistics

62 3.7 Sub-Menu tree for DIAGNOSTIC 3.7.1. Loopback function SYSTEM DIAGNOSTIC Î DIAG LOOPBACK Note : there is no SYSTEM DIAGNOSTIC menu on the

Seite 125

65 3.7.2. BER Test function SYSTEM DIAGNOSTIC Î DIAG BER TEST This is the internal Bit Error Rate Tester (BERT) for complete testing of local and

Seite 126

66 4. Parameters Table There are many parameters tables for end user easily to write down all setting of devices before installing those on sites.

Seite 127

67 4.2 SHDTU03b-Data 4.2.1. SHDTU03b-Data -- Serial interface mode NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F □G PSD

Seite 128

68 4.3 SHDTU03b-ET100 4.3.1. SHDTU03b-ET100 -- Ethernet interface mode NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F

Seite 129

69 4.4 SHDTU03b-31 4.4.1. SHDTU03b-31 -- E1 Interface mode Interface E1 □Serial □Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-

Seite 130

6. APPENDIX ...

Seite 131

70 4.4.2. SHDTU03b-31 -- Serial Interface mode Interface □E1 Serial □Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK □

Seite 132

71 4.4.3. SHDTU03b-31 -- Ethernet Interface mode Interface □E1 □Serial Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Seite 133

72 4.4.4. SHDTU03b-31 -- E1+Serial Interface mode Interface □E1 □Serial □Ethernet E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Seite 134

73 4.4.5. SHDTU03b-31 -- E1+Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Seite 135 - 5.8 Upgrade

74 4.5 SHDTU03b-E1/T1 4.5.1. SHDTU03b-E1/T1 -- E1 Interface mode Interface E1 □T1 NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A

Seite 136

75 4.5.2. SHDTU03b-E1/T1 -- T1 Interface mode Interface □E1 T1 NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F □G PSD

Seite 137

76 4.6 SHDTU03b-31T 4.6.1. SHDTU03b-31T -- E1 Interface mode Interface E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+E

Seite 138

77 4.6.2. SHDTU03b-31T -- T1 Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet T1 □T1+Serial □T1+Ethernet NTU Type □

Seite 139 - 5.9 Diagnostic

78 4.6.3. SHDTU03b-31T -- Serial Interface mode Interface □E1 Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NTU Ty

Seite 140

79 4.6.4. SHDTU03b-31T -- Ethernet Interface mode Interface □E1 □Serial Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NTU

Seite 142 - 5.10 Exit

80 4.6.5. SHDTU03b-31T -- E1+ Serial Interface mode Interface □E1 □Serial □Ethernet E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NT

Seite 143

81 4.6.6. SHDTU03b-31T -- E1 + Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial E1+Ethernet □T1 □T1+Serial □T1+Ethernet

Seite 144 - 6. Appendix

82 4.6.7. SHDTU03b-31T -- T1+ Serial Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 T1+Serial □T1+Ethernet NT

Seite 145

83 4.6.8. SHDTU03b-31T -- T1 + Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial T1+Ethernet

Seite 146

84 5. Configuration with Console Port This chapter will deal with the details of configuration and operation of this product via console port with

Seite 147

85 5.1 Login Procedure At the start up screen, you will see: Press the SPACE key until the login screen appears. When you see

Seite 148

86 5.2 Window structure After you type the password, it will display the main menu. Above captured screen shows the common struc

Seite 149

87 5.3 Main Menu Summary The main menu is prompted as following: Menu Title Function Setup Use this menu to setup SHDSL type, SHDSL paramet

Seite 150

88 5.4 Configuration This section provides information about the configuration of SHDSL .Bis NTU. Follow the procedures: In the main menu, select

Seite 151

89 5.4.1. Configure NTU Interface Setup Interface

Seite 152 - 6.5 Console Cable

9 1. Introduction The G.SHDSL.bis NTU offers four different interfaces (E1,T1, Serial and Ethernet) connecting customers to high-speed TDM servi

Seite 153 - 6.6 E1/T1 Balanced Cable

90 If the SHDSL.bis NTU is a multi-interface model, it will display more types of interfaces that can be selected. Use the [TAB] key to choose the dif

Seite 154 - 6.7 E1 Unbalanced Cable

91 5.4.2. Configure SHDSL parameters This section shows how to setup the SHDSL parameters: SHDSL Mode, Annex type, Psd Mask, SNR margin. Select Sh

Seite 155 - 6.8 Ethernet Cable

92 To set the SHDSL Annex type, move the cursor to Annex and press [ENTER]. Select the annex type by using [TAB] key. Set Up SHDSL parameter, Annex

Seite 156 - 6.9 DSL Cable

93 To set the SHDSL Margin, move the cursor to margin and press [ENTER]. Select the margin via [TAB] key and key in the Next margin. Setup SHDSL para

Seite 157 - 6.10 Power Cord

94 5.4.3. Configure E1 parameters When using E1 interface, select the E1 item and press [ENTER] or [RIGHT]. The E1 setting includ

Seite 158 - Å----ÆPIN5

95 Framing Framing is required to recover the channelized E1. In transparent operation, the framing is configured as Unframed. In this case the G.SH

Seite 159 - Å---ÆPIN20

96 FAS Data Data Data Data Data Data Data Data01234567831Time Slots64k 64k 64k 64k 64k 64k 64k 64k 64k 64k1408k9 ~ 30 ITU 991.2 (2004) (G.SHD

Seite 160

97 FAS01234 1631Time Slots64k 64k 64k 64k 64k 64k 64k896k17 ~ 30CAS5 ~ 15704kData Data Data Data Data Data Data Data Data Data Data01234567831Time Slo

Seite 161

98 Setup E1 Parameter, Pass Through When SHDSL.bis using 2-pairs(4-wires), the time slot number can only use even number When se

Seite 162

99 For example, when channel framing is PCM30 or PCM30C (with time slot number is 30 and first time slot is 1) refer to the following graphic. When P