With IMC-1000MS reset to factory default, connect a PC and configure the PC to the 10.1.1.0 network (10.1.1.100 recommended). Use a
PC to ping IMC-1000MS at its factory default IP address of 10.1.1.1. With a direct connection to PC, there should be no time outs and ping
latency should be less than 1 millisecond. If you switch to another IMC-1000MS, be sure to clear the PC ARP table. Every IMC-1000MS has
the same default IP address, but every unit has a different MAC address. To clear the PC’s MAC table, open a command window and execute
the command ‘arp –d’. In addition, if you disconnect the PC from any LAN connection and then re-connect, the ARP table should also be
cleared.
With IMC-1000MS reset to factory default, connect a PC and configure the PC to the 10.1.1.0 network (10.1.1.100 recommended). Use a
PC to connect to IMC-1000MS at its factory default IP address of 10.1.1.1 using a web browser (Internet Explorer, Firefox, Chrome, etc.). The
local web page login page should display. Use ‘admin/admin’ to login; the local main page should be displayed in the browser.
43
3.11.4.2PingTest
3.11.4.3WebAccessTest
If the ping test can pass and the login page can be displayed but login fails, we recommend that cookies be deleted. You may either delete