FRM220-NMC
Management System - Graphical User Interface
Chassis List
Use the "Chassis List" control to select the
chassis in the cascade group. Using only
one IP address and one single point of
management, up to 10 chassis (ID 0~9)
can be managed.
Language
The NMC currently supports four different
language interfaces; English, Simplified
Chinese, Traditional Chinese and
Japanese user interfaces.
Header
The top header of Figure 3.3 displays the chassis ID (0 for the master chassis, 1~9 for
cascaded slave chassis), the slot number for NMC is always 1, NMC is always in local and
the version displayed in the format h/w-s/w. In the below example, the NMC hardware
version is 1.0 while the software version is 3.263 and kernel build 14622.
Chassis Information
The Chassis Information
group displays the power
supply types and the
power and fan status.
There are slots for installing
one or two power modules.
They may hold either AC or
DC type modules. Power 1
refers to the module
installed in the left slot as
viewed from the rear of the
chassis, while Power 2 refers
to the right slot. An OK
status indicates the power
module is working within
normal parameters. Fan
status is indicated with both
the current RPM (speed) of
the cooling fans and with a
status of OK or Failed. If the
RPM of the fan falls below
1650RPM, a failed status will
be indicated.
Clicking on the "System" item will display an
overview screen (Figure 3.2) that allows setting
system information, TFTP kernel and file system
update, date & time setting, and parameter
management.
Figure 3.1 Selectable features of the Main Web GUI
Figure 3.2 System Information
The Web GUI of FRM220-NMC behaves just like any other web based application. The following graphic (Figure 3.1) shows all of the
areas that may be clicked for further configuration. Slots without any line card or without manageable line card will be shown as 'Empty'.
Figure 3.3 SNMP+Chassis Information
System Information
Click on "SNMP+Chassis" from the left hand window menu bar.
SNMP + Chassis
255.255.255.240Netmask
Target Name
Kernel File Name
Target IP
System Information
Date and Time Information
Function Key
Time Function Key
Parameter Management
Gateway IP
TFTP Server IP
File-System File Name
MAC AddressSerial NumberModel
FRM220
kernel14622.gz
romfs326.gz
59.125.162.252
59.125.162.241
59.125.162.243.
00:02:AB:0D:64:FC000000FRM220
Chassis ID Slot
Alarm 1 Settings
Alarm 2 Settings
Side Type Version
00 01 Local SNMP 1.00-3.26#14622
Chassis Information
Alarm Information
Function Key
Redundancy Mode
Mode
Mode
DC36-75V
Type Status
StatusRPM
Type Status
StatusRPM
Power 1
Fan 1
User 1
Chassis
Local
Remote
Power 2
Fan 2
OK
OK
10/100I Series only.Disable
OKAC90-250v
OK37953855
By Powers
By Fans
Inactive
Set Parameters Refresh Status
Inactive
Alarm 1 Status Alarm 2 Status
Power1
Fan1
Power2
Fan2
FX Link Down
FX Link Down
* *
UTP Link Down
UTP Link Down
FEF Datect Remote Power Fail
Signal Loss
Signal Loss
User 2
Chassis
Local
Remote
Power1
Fan1
Power2
Fan2
FX Link Down
FX Link Down
* *
UTP Link Down
UTP Link Down
FEF Datect Remote Power Fail
Signal Loss
Signal Loss
3-6
FRM220-NMC GUI