User Manual
FRM220
In-band Managed
Fiber Media Platform Rack
20 Slot, 2U
CTC Union Technologies Co., Ltd.
Seitenansicht 0
1 2 3 4 5 6 ... 71 72

Inhaltsverzeichnis

Seite 1 - User Manual

User Manual FRM220 In-band Managed Fiber Media Platform Rack 20 Slot, 2U CTC Union Technologies Co., Ltd.

Seite 2

Chapter 1 Introduction 10 1.8 Fiber Optical Options Fiber access connectors are provided for fiber optic cable connection on each line card.

Seite 3 - FRM220 User Manual

Chapter 1 Introduction 11 1.9 FRM220 Application The FRM220 is an excellent choice for complimenting fiber infrastructure in Metro LAN, campus, cor

Seite 4

Chapter 1 Introduction 12

Seite 5 - Table of Contents

Chapter 2 Installation 13 Chapter 2 Installation 2.1 Introduction The Installation chapter will cover the physical installation of the FRM22

Seite 6

Chapter 2 Installation 14 2.3.2 Fan Units Removal/Replacement Figure 2-2 Removal/Replacement of FRM220 Fan Units 2.3.3 L

Seite 7

Chapter 2 Installation 15 2.4 Electrical Installation With an AC power module, AC power is supplied to the FRM220 through a standard IEC 3-prong r

Seite 8

Chapter 2 Installation 16 2.6 Chassis Cascade The FRM220 chassis may be cascaded in such a manner that only one single IP address is required to m

Seite 9

Chapter 2 Installation 17 2.7 Power Modules Removal/Replacement The Power Supply Modules in the FRM220 are available in three versions, one A

Seite 10 - Chapter 1 Introduction

Chapter 2 Installation 18 2.8 Installation 2.6.1 Line Card Installation The Line Cards for the FRM220 are Fiber Media Converter Cards which slide i

Seite 11

Chapter 3 Provisioning 19 Chapter 3 Provisioning 3.1. Introduction This chapter will go into the details of the specific provisioning and operatio

Seite 13 - Chapter 2 Installation

Chapter 3 Provisioning 20 3.2 Console Mode 3.2.1 Control Port General The FRM220 SNMP Console Port, labeled 'Console' on the ca

Seite 14

Chapter 3 Provisioning 21 3.2.4 Terminal Login To enter "Console mode", a password is required. Normally, there is no password set f

Seite 15

Chapter 3 Provisioning 22 3.2.5 TCP/IP Configuration The Network Management modes that require TCP/IP communications must first have all

Seite 16

Chapter 3 Provisioning 23 Step Two: Manager Configuration Process a.) Assign Managers ****************************************

Seite 17

Chapter 3 Provisioning 24 b.) Trap Management From the SNMP Manager Configuration Menu, select 'N' for trap management configuration.

Seite 18

Chapter 3 Provisioning 25 3.2.6 Chassis Information and Alarm setup From the main menu of the FRM220, press the '1' (one) key to enter t

Seite 19 - Chapter 3 Provisioning

Chapter 3 Provisioning 26 For an example of configuration for Alarm #2, press '5' (five). Alarm#2 Mode: <0>: Disable -- ignor

Seite 20

Chapter 3 Provisioning 27 3.2.7 User Password Setup From the main menu page, press the 'P' key to enter the Password Setup. << Pass

Seite 21

Chapter 3 Provisioning 28 3.2.8.4 Setup the FRM220 The following screens will show the detailed procedures to setup the networking for the FRM220 an

Seite 22

Chapter 3 Provisioning 29 Ping the NMC from the TFTP server PC and be sure there is a response. Place the upgrade file(s) in the s

Seite 23

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District Taipei 114 Taiwa

Seite 24

Chapter 3 Provisioning 30 OK, now let's verify the version number of the SNMP. Login to the terminal of the FRM220. Note that the version is n

Seite 25

Chapter 4 Web Based Management 31 Chapter 4 Web Based Management 4.1 Introduction This chapter will explain the operation of the FRM GUI (Graphical

Seite 26

Chapter 4 Web Based Management 32 After a successful login, the home page for the rack will be displayed. All card inventory and LED status are show

Seite 27

Chapter 4 Web Based Management 33 The Web GUI behaves just like any other web based application. The following graphic shows all of the areas that m

Seite 28

Chapter 4 Web Based Management 34 4.3.2.2 View SNMP & Chassis Click on "SNMP+Chassis" from the left hand window menu bar.

Seite 29

Chapter 4 Web Based Management 35 4.32.3 Edit the SNMP Agent Click on "Edit" from the window menu bar to enter the Edit SNMP Agent Window.

Seite 30

Chapter 4 Web Based Management 36 4.33 Operation The interface for the WEB is a point and click application that requires little use of the keyboard.

Seite 31 - 4.2.2 Configuration

Chapter 4 Web Based Management 37 4.33.1 Rack Detail From this main display, we can view the details of any rack by clicking on the "Rack"

Seite 32

Chapter 4 Web Based Management 38

Seite 33

Chapter 5 Troubleshooting 39 5.4 Troubleshooting 5.41 Network Settings 5.41.1 Review Agent Settings During unit startup, the "SNMP" LED wil

Seite 34

Legal The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union

Seite 35

Chapter 5 Troubleshooting 40 5.41.2 Review Manager Settings For the browser to connect to the FRM for management, the FRM's SNMP must be properl

Seite 36

Appendix A 41 Fiber (SC Type) LED Indicators 10/100 Ethernet CPU Chip Appendix A. Line Cards Introduction The FRM220 In-Band Managed Media Converter

Seite 37

Appendix A 42 Link Fault Pass Through (LFP, AKA. Link Loss Forwarding) This media converter incorporates a Link Forwarding feature which allows indir

Seite 38

Appendix A 43 LED Status Indicators LED Function State Status PWR Power indicator On Converter has power. Off Converter has no power or h

Seite 39 - Chapter 5 Troubleshooting

Appendix A 44 Below is an example of managing the remote MC via OAM. **************************************** *** CTC U

Seite 40

Appendix A 45 A.2 FRM220-1000A In-band (802.3ah) Managed Fiber Gigabit Media Converter (to be announced) The FRM220-1000A is an IEEE802.3ah in-ban

Seite 41 - Appendix A

Appendix A 46 The FRM-1000 line card is an Ethernet Fiber Media Converter that is compliant with IEE802.3z 1000BASE-TX or Gigabit Ethernet and 1000

Seite 42

Appendix A 47 A.3 FRM220-FXO/FXS In-band Managed POTS/PSTN Fiber Converter

Seite 43

Appendix A 48

Seite 44

Appendix A 49 Fiber Media Connection (SC Type Status LEDs Data port connection Configuration DIP switch A.4 FRM220-Serial In-band Managed Datacom Fib

Seite 45

Table of Contents i Chapter 1 Introduction...

Seite 46

Appendix A 50 The FRM-Serial is designed to provide two clear channels in each direction. In an RS-232 5-wire application, one channel is used for da

Seite 47

Appendix A 51 Serial Line Card Detail The following is the display screen for the Serial fiber converter. Slot #05 SERIAL Select Menu:

Seite 48

Appendix A 52 A.5 FRM220-E1/T1 In-band Managed G.703 Fiber Media Converter (to be announced) The FRM-E1 and FRM-T1 are high-performance G.703 E

Seite 49

Appendix A 53 The FRM-E1 and FRM-T1 fiber media converters' transmissions are transparent to clock and data. They are designed to be placed

Seite 50

Appendix A 54 DIP Setting Function Description OFF HDB3 (BZ8S) 1 ON AMI Line Code OFF Disable 2 ON Enable FEF 3 4 Loop Back Selection OFF O

Seite 51

Appendix A 55 E1 / T1 Line Card Detail The following is the display screen for the E1 BNC fiber converter. Slot #03 E1 BNC Select Menu:

Seite 52

Appendix A 56 A.6 FRM220-Data (to be announced) The FRM-DATA is a high-performance serial over fiber media converter. These converters fully support

Seite 53

Appendix A 57 Clocking Modes There are three clocking schemes for the FRM-DATA converters, shown below. Int. Recovery Ext. Recove

Seite 54

Appendix A 58 LED Status LED Detailed Description LED Function State Status PWR Power indicator On Converter has power Off Converter has

Seite 55

Appendix A 59 Loop Back Features of the FRM220-DATA The FRM220-DATA features local and remote loop back functions for both the data por

Seite 56

Table of Contents ii Appendix A. Line Cards...

Seite 57

Appendix A 60 DIP Switch Settings of the FRM-DATA (DIP SW 1) DIP SW1 STATE Function Description 1 2 Timing mode select: OFF OFF Transparent ON

Seite 58

Appendix A 61 DIP Switch Settings of the FIB1-DATA (DIP SW 2) DIP Switch Number 2 Table Switch and State Function Description 1 Data port RC pola

Seite 59

Appendix A 62 When the FRM-DATA is ordered with a V.35 interface, the unit comes with a HDB26 male to MB34 Female adapter cable, 1 meter long. The pi

Seite 60

Appendix A 63 When the FRM-DATA is ordered with a RS-530 interface, the unit comes with a HDB26 male to DB25 Female adapter cable, 1 meter long. The

Seite 61

Appendix A 64 When the FRM-DATA is ordered with a RS-449 interface, the unit comes with a HDB26 male to DB37 Female adapter cable, 1 meter long. The

Seite 62

Appendix A 65 When the FRM-DATA is ordered with a X.21 interface, the unit comes with a HDB26 male to DB15 Female adapter cable, 1 meter long.

Seite 63

Appendix A 66 DSR constantly ON, except during tests DCD constantly ON, except during signal loss Test Loops LLB (Local Loop Back) RLB (Remote

Seite 64

Appendix A 67 6: This key will reset the card settings to factory default. R: This key will refresh the screen display. N: This key selects the second

Seite 65

Appendix A 68 Data Line Card Detail (second page) ************************************************************** *** CTC UNION TECHNOLOGIES CO., L

Seite 66

Appendix A 69 A.7 FRM220-10/100A In-band Managed (IEEE802.3ah) Fiber Ethernet Media Converter (to be announced)

Seite 67

Chapter 1 Introduction 7 Chapter 1 Introduction 1.0 Introduction Thank you for choosing the FRM220 Platform Fiber Media Converter Rack. If you would

Seite 68

Appendix A 70

Seite 70

Fiber Series CTC Union Technologies Co., Ltd. Far Eastern Vienna Technologies Center

Seite 71

Chapter 1 Introduction 8 1.3 Chassis Rear Description The rear panel holds the chassis interface, the hot-swappable cooling fan modules,

Seite 72 - Fiber Series

Chapter 1 Introduction 9 1.5 Chassis Specifications Environment Temperature 0 - 65°C (32-150°F) Humidity 10-90% non condensing Alarm relay conta